mirror of
https://github.com/soarqin/DSP_Mods.git
synced 2026-11-19 17:05:20 +08:00
Add Proto-backed planning, fixed-building analysis, blueprint capture, and facility-specific material and power calculations. Migrate belt-signal upstream statistics, include review fixes, and document the architecture and manual validation workflow.
135 lines
6.4 KiB
C#
135 lines
6.4 KiB
C#
using System;
|
|
using System.Collections.Generic;
|
|
using System.Linq;
|
|
|
|
namespace UXAssist.Production;
|
|
|
|
public sealed class AccumulatorExchangeAdapter : IProductionProcessAdapter
|
|
{
|
|
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
|
|
{
|
|
return recipe?.Category == ProductionRecipeCategory.Exchange ||
|
|
recipe == null && building?.Kind == ProductionBuildingKind.Exchanger;
|
|
}
|
|
|
|
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
|
|
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
|
|
out ProductionProcess process, out ProductionDiagnostic diagnostic)
|
|
{
|
|
process = null;
|
|
diagnostic = null;
|
|
if (building != null && building.Kind != ProductionBuildingKind.Exchanger)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
|
|
"This building cannot charge or discharge accumulators.", recipeId: recipe?.Id ?? 0,
|
|
buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
|
"Accumulator exchange supports native speedup only.", recipeId: recipe?.Id ?? 0);
|
|
return false;
|
|
}
|
|
|
|
var speedBonus = 0.0;
|
|
if (mode != ProliferationMode.None &&
|
|
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out _, out _)))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
|
"The accumulator proliferation level is unavailable.", recipeId: recipe?.Id ?? 0);
|
|
return false;
|
|
}
|
|
|
|
var state = 0;
|
|
if (recipe != null)
|
|
{
|
|
if (recipe.Inputs.Count != 1 || recipe.Outputs.Count != 1 ||
|
|
recipe.Inputs.Single().Value != 1 || recipe.Outputs.Single().Value != 1)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
|
|
"Accumulator exchange requires one empty/full item conversion.", recipeId: recipe.Id);
|
|
return false;
|
|
}
|
|
|
|
var inputId = recipe.Inputs.Single().Key;
|
|
var outputId = recipe.Outputs.Single().Key;
|
|
state = building == null || inputId == building.EmptyAccumulatorItemId &&
|
|
outputId == building.FullAccumulatorItemId ? 1 :
|
|
inputId == building.FullAccumulatorItemId &&
|
|
outputId == building.EmptyAccumulatorItemId ? -1 : 0;
|
|
if (state == 0)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
|
"The exchanger's accumulator items do not match the recipe.", recipeId: recipe.Id);
|
|
return false;
|
|
}
|
|
}
|
|
else if (operatingParameters == null ||
|
|
!operatingParameters.TryGetValue("Mode0", out var selectedMode) ||
|
|
double.IsNaN(selectedMode) || double.IsInfinity(selectedMode) ||
|
|
selectedMode != Math.Truncate(selectedMode) ||
|
|
selectedMode < -1 || selectedMode > 1)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"Provide the exchanger's native charging, discharging, or idle mode.",
|
|
buildingItemId: building?.ItemId ?? 0);
|
|
return false;
|
|
}
|
|
else
|
|
{
|
|
state = (int)selectedMode;
|
|
}
|
|
|
|
if (recipe != null && operatingParameters != null &&
|
|
operatingParameters.TryGetValue("Mode0", out var requestedMode) && requestedMode != state)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
|
"The exchanger's operating mode conflicts with the selected recipe.", recipeId: recipe.Id);
|
|
return false;
|
|
}
|
|
|
|
var inputItem = recipe?.Inputs.Single().Key ??
|
|
(state == 1 ? building.EmptyAccumulatorItemId : building.FullAccumulatorItemId);
|
|
var outputItem = recipe?.Outputs.Single().Key ??
|
|
(state == 1 ? building.FullAccumulatorItemId : building.EmptyAccumulatorItemId);
|
|
if (state != 0 && (inputItem <= 0 || outputItem <= 0))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"The exchanger's accumulator items are unavailable.", buildingItemId: building?.ItemId ?? 0);
|
|
return false;
|
|
}
|
|
|
|
if (building != null && state != 0 &&
|
|
(!FinitePositive(building.ExchangeRateWatts) || !FinitePositive(building.AccumulatorEnergyJoules)))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"The exchanger's energy capacity is unavailable.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
var effectiveWatts = building == null || state == 0 ? 0 : building.ExchangeRateWatts * (1 + speedBonus);
|
|
var cycles = building == null ? 0 : state == 0 ? 1 :
|
|
effectiveWatts * 60 / building.AccumulatorEnergyJoules;
|
|
var inputs = state == 0 ? Array.Empty<KeyValuePair<int, double>>() :
|
|
new[] { new KeyValuePair<int, double>(inputItem, 1) };
|
|
var outputs = state == 0 ? Array.Empty<KeyValuePair<int, double>>() :
|
|
new[] { new KeyValuePair<int, double>(outputItem, 1) };
|
|
process = new ProductionProcess(recipe?.Id ?? 0, building?.ItemId ?? 0,
|
|
state == 0 ? ProliferationMode.None : mode, state == 0 ? 0 : level,
|
|
inputs, outputs, cycles, state == 1 ? effectiveWatts : building?.IdlePowerWatts ?? 0,
|
|
building != null, accumulatorChargingWatts: state == 1 ? effectiveWatts : 0,
|
|
accumulatorDischargingWatts: state == -1 ? effectiveWatts : 0,
|
|
sprayedInputsPerCycle: state == 0 ? 0 : 1,
|
|
preservedSpraysPerCycle: mode == ProliferationMode.None
|
|
? Array.Empty<KeyValuePair<int, double>>() : outputs);
|
|
return true;
|
|
}
|
|
|
|
private static bool FinitePositive(double value)
|
|
{
|
|
return value > 0 && !double.IsNaN(value) && !double.IsInfinity(value);
|
|
}
|
|
}
|