Files
DSP_Mods/UXAssist/Production/LaunchProcessAdapter.cs
T
soarqin d4ba72abf4 fix(production): correct full-load capture and solver scaling
Stop capturing the transient miner output damper, apply the sandbox boost state to artificial stars as for launchers, and keep lens-free photon flows when no ray receiver is selected.

Scale the planner conservation check by each ledger row and normalize the simplex right-hand side so large rates no longer fail. Skip non-production objects before copying native settings, decode blueprints through the native paste path, and simplify analyzer mode resolution.

Update stale ProductionCheck expectations, add regression checks, and document the rules.
2026-10-11 03:13:07 +08:00

103 lines
4.6 KiB
C#

using System;
using System.Collections.Generic;
namespace UXAssist.Production;
public sealed class LaunchProcessAdapter : IProductionProcessAdapter
{
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
{
return building?.Kind == ProductionBuildingKind.Ejector || building?.Kind == ProductionBuildingKind.Silo;
}
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
out ProductionProcess process, out ProductionDiagnostic diagnostic)
{
process = null;
diagnostic = null;
if (recipe != null)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
"Launchers consume ammunition without producing a recipe item.", recipeId: recipe.Id,
buildingItemId: building.ItemId);
return false;
}
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"Launch ammunition supports native speedup only.", buildingItemId: building.ItemId);
return false;
}
if (operatingParameters == null ||
!operatingParameters.TryGetValue("LaunchAvailable", out var launchAvailable) ||
(launchAvailable != 0 && launchAvailable != 1))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Specify whether a usable orbit or Dyson-sphere node is available.",
buildingItemId: building.ItemId);
return false;
}
if (launchAvailable == 0)
{
process = new ProductionProcess(0, building.ItemId, ProliferationMode.None, 0,
Array.Empty<KeyValuePair<int, double>>(), Array.Empty<KeyValuePair<int, double>>(),
1, building.IdlePowerWatts, true);
return true;
}
if (building.LaunchChargeTicks <= 0 || building.LaunchCooldownTicks <= 0 ||
building.AmmunitionItemId <= 0 || !catalog.Items.ContainsKey(building.AmmunitionItemId))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
"The launcher's native ammunition or cycle timings are unavailable.",
buildingItemId: building.ItemId);
return false;
}
if (!SandboxBoost.TryResolve(operatingParameters, SandboxBoost.ModeKey(building), building.ItemId,
out var boosted, out diagnostic))
return false;
var speedBonus = 0.0;
var powerMultiplier = 1.0;
if (mode != ProliferationMode.None &&
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out _, out powerMultiplier)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"The launch ammunition's proliferation level is unavailable.",
buildingItemId: building.ItemId);
return false;
}
var nativeStep = Math.Truncate(10000 * (1 + speedBonus) + 0.1) * (boosted ? 10 : 1);
if (nativeStep <= 0 || double.IsInfinity(nativeStep) || double.IsNaN(nativeStep))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The launcher's native speed is outside the supported range.", buildingItemId: building.ItemId);
return false;
}
var cycleTicks = Math.Ceiling(building.LaunchChargeTicks * 10000.0 / nativeStep) +
Math.Ceiling(building.LaunchCooldownTicks * 10000.0 / nativeStep);
var launchesPerMinute = 3600.0 / cycleTicks;
if (launchesPerMinute <= 0 || double.IsInfinity(launchesPerMinute) ||
double.IsNaN(launchesPerMinute))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The launcher cycle is outside the supported range.", buildingItemId: building.ItemId);
return false;
}
process = new ProductionProcess(0, building.ItemId, mode,
mode == ProliferationMode.None ? 0 : level,
new[] { new KeyValuePair<int, double>(building.AmmunitionItemId, 1) },
Array.Empty<KeyValuePair<int, double>>(), launchesPerMinute,
building.WorkingPowerWatts * powerMultiplier, true, launchesPerCycle: 1);
return true;
}
}