Files
DSP_Mods/UXAssist/Production/RayReceiverAdapter.cs
T
soarqin 51e90a8e1d fix(production): correct full-load capture and solver scaling
Stop capturing the transient miner output damper, apply the sandbox boost state to artificial stars as for launchers, and keep lens-free photon flows when no ray receiver is selected.

Scale the planner conservation check by each ledger row and normalize the simplex right-hand side so large rates no longer fail. Skip non-production objects before copying native settings, decode blueprints through the native paste path, and simplify analyzer mode resolution.

Update stale ProductionCheck expectations, add regression checks, and document the rules.
2026-10-25 22:01:05 +08:00

181 lines
8.7 KiB
C#

using System;
using System.Collections.Generic;
namespace UXAssist.Production;
public sealed class RayReceiverAdapter : IProductionProcessAdapter
{
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
{
return building?.Kind == ProductionBuildingKind.RayReceiver ||
recipe?.Category == ProductionRecipeCategory.PhotonStore;
}
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
out ProductionProcess process, out ProductionDiagnostic diagnostic)
{
process = null;
diagnostic = null;
if (building == null)
return TryEvaluateWithoutReceiver(recipe, mode, operatingParameters, out process, out diagnostic);
if (building.Kind != ProductionBuildingKind.RayReceiver)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
"The selected building cannot receive Dyson-sphere rays.", recipeId: recipe?.Id ?? 0,
buildingItemId: building.ItemId);
return false;
}
if (building.RatedGenerationWatts <= 0 || !Finite(building.RatedGenerationWatts) ||
(recipe != null && (recipe.Category != ProductionRecipeCategory.PhotonStore ||
recipe.Inputs.Count != 0 || recipe.Outputs.Count != 1 ||
!recipe.Outputs.ContainsKey(building.PowerProductItemId))))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
"The receiver's native photon product or power rating does not match the recipe.",
recipeId: recipe?.Id ?? 0, buildingItemId: building.ItemId);
return false;
}
var photonMode = recipe != null;
if (operatingParameters == null)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Provide the receiver's operating settings.", buildingItemId: building.ItemId);
return false;
}
var hasMode = operatingParameters.TryGetValue("Mode0", out var selectedMode);
if (!hasMode && !photonMode ||
hasMode && (selectedMode != 0 && selectedMode != building.PowerProductItemId ||
photonMode && selectedMode != building.PowerProductItemId))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Select the receiver's grid or native photon operating mode.",
recipeId: recipe?.Id ?? 0, buildingItemId: building.ItemId);
return false;
}
if (recipe == null && selectedMode > 0) photonMode = true;
if (photonMode && (building.PowerProductItemId <= 0 ||
building.PowerProductEnergyJoules <= 0 ||
!Finite(building.PowerProductEnergyJoules) ||
!catalog.Items.ContainsKey(building.PowerProductItemId)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"The ray receiver has no valid native photon product or required photon energy.",
buildingItemId: building.ItemId);
return false;
}
if (!operatingParameters.TryGetValue("LensItemId", out var lensId) ||
lensId < 0 || lensId > int.MaxValue || lensId != Math.Truncate(lensId))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Provide the receiver's lens item ID, or zero for no lens.", buildingItemId: building.ItemId);
return false;
}
ProductionItem lens = null;
if (lensId > 0 && (!catalog.Items.TryGetValue((int)lensId, out lens) ||
(lens.CatalystTypeMask & building.CatalystMask) == 0 ||
lens.CatalystAbilityMultiplier <= 0 || !Finite(lens.CatalystAbilityMultiplier)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The selected item is not a compatible ray-receiver lens.",
itemId: (int)lensId, buildingItemId: building.ItemId);
return false;
}
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup ||
mode == ProliferationMode.Speedup && lens == null)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"Only an installed lens can receive native ray-receiver speedup.", buildingItemId: building.ItemId);
return false;
}
var speedBonus = 0.0;
if (mode != ProliferationMode.None &&
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out _, out _)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"The lens's proliferation level is unavailable.", buildingItemId: building.ItemId);
return false;
}
var energyWatts = building.RatedGenerationWatts * 2.5 *
(lens?.CatalystAbilityMultiplier ?? 1) *
(1 + speedBonus) * (photonMode ? 8 : 1);
var cyclesPerMinute = photonMode
? energyWatts * 60 / building.PowerProductEnergyJoules : 1;
if (cyclesPerMinute <= 0 || !Finite(cyclesPerMinute) || !Finite(energyWatts))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The receiver's native output is outside the supported range.", buildingItemId: building.ItemId);
return false;
}
var lossKnown = operatingParameters.TryGetValue("SolarEnergyLossRate", out var solarLoss);
if (lossKnown && (solarLoss < 0 || solarLoss >= 1 || !Finite(solarLoss)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"Solar energy loss must be a finite fraction below one.", buildingItemId: building.ItemId);
return false;
}
if (!lossKnown)
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"The Dyson-sphere power requirement needs the current solar energy loss technology setting.",
buildingItemId: building.ItemId);
var lensFlow = lens == null ? Array.Empty<KeyValuePair<int, double>>() :
new[] { new KeyValuePair<int, double>(lens.Id, 0.1 / cyclesPerMinute) };
var productFlow = photonMode
? new[] { new KeyValuePair<int, double>(building.PowerProductItemId, 1) }
: Array.Empty<KeyValuePair<int, double>>();
process = new ProductionProcess(recipe?.Id ?? 0, building.ItemId, mode,
mode == ProliferationMode.None ? 0 : level, lensFlow, productFlow,
cyclesPerMinute, building.WorkingPowerWatts, true,
generationWatts: photonMode ? 0 : energyWatts,
dysonSphereRequirementWatts: lossKnown ? energyWatts / (1 - solarLoss * 0.6) : (double?)null,
powerKnown: lossKnown);
return true;
}
// Photon output per cycle does not depend on the receiver, but lens wear, speedup, and power do.
private static bool TryEvaluateWithoutReceiver(ProductionRecipe recipe, ProliferationMode mode,
IReadOnlyDictionary<string, double> operatingParameters, out ProductionProcess process,
out ProductionDiagnostic diagnostic)
{
process = null;
diagnostic = null;
if (recipe.Inputs.Count != 0 || recipe.Outputs.Count != 1)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
"A photon recipe must have one output and no inputs.", recipeId: recipe.Id);
return false;
}
if (mode != ProliferationMode.None ||
operatingParameters != null && operatingParameters.TryGetValue("LensItemId", out var lensId) &&
lensId != 0)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingBuilding,
"Select a ray receiver to evaluate lens consumption and speedup.", recipeId: recipe.Id);
return false;
}
process = new ProductionProcess(recipe.Id, 0, ProliferationMode.None, 0,
Array.Empty<KeyValuePair<int, double>>(), recipe.Outputs, 0, 0, false);
return true;
}
private static bool Finite(double value)
{
return !double.IsNaN(value) && !double.IsInfinity(value);
}
}