mirror of
https://github.com/soarqin/DSP_Mods.git
synced 2026-11-19 17:05:20 +08:00
Stop capturing the transient miner output damper, apply the sandbox boost state to artificial stars as for launchers, and keep lens-free photon flows when no ray receiver is selected. Scale the planner conservation check by each ledger row and normalize the simplex right-hand side so large rates no longer fail. Skip non-production objects before copying native settings, decode blueprints through the native paste path, and simplify analyzer mode resolution. Update stale ProductionCheck expectations, add regression checks, and document the rules.
101 lines
4.4 KiB
C#
101 lines
4.4 KiB
C#
using System;
|
|
using System.Collections.Generic;
|
|
|
|
namespace UXAssist.Production;
|
|
|
|
public sealed class MiningProcessAdapter : IProductionProcessAdapter
|
|
{
|
|
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
|
|
{
|
|
return recipe == null && building?.Kind == ProductionBuildingKind.Miner;
|
|
}
|
|
|
|
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
|
|
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
|
|
out ProductionProcess process, out ProductionDiagnostic diagnostic)
|
|
{
|
|
process = null;
|
|
diagnostic = null;
|
|
if (building.MiningPeriodTicks <= 0 || building.MinerKind == ProductionMinerKind.None)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
|
|
"The mining building has no native period or resource type.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
if (operatingParameters == null ||
|
|
!operatingParameters.TryGetValue("ResourceItemId", out var outputId) ||
|
|
!ValidItemId(outputId) || !catalog.Items.ContainsKey((int)outputId) ||
|
|
!operatingParameters.TryGetValue("MiningSpeedMultiplier", out var miningSpeed) ||
|
|
!FinitePositive(miningSpeed))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"Provide the resource item and mining technology speed.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
var resourceFactor = 1.0;
|
|
if (building.MinerKind == ProductionMinerKind.Vein &&
|
|
(!operatingParameters.TryGetValue("VeinCount", out resourceFactor) ||
|
|
resourceFactor != Math.Truncate(resourceFactor) || !FinitePositive(resourceFactor)))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"Provide the number of covered veins.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
if (building.MinerKind == ProductionMinerKind.Oil &&
|
|
(!operatingParameters.TryGetValue("OilUnits", out resourceFactor) ||
|
|
!FinitePositive(resourceFactor)))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"Provide the covered oil well's native flow factor.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
var machineSpeed = 1.0;
|
|
if (operatingParameters.TryGetValue("MachineSpeedFactor", out var suppliedSpeed))
|
|
{
|
|
if (!FinitePositive(suppliedSpeed))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
|
"The miner speed factor must be positive.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
machineSpeed = suppliedSpeed;
|
|
}
|
|
|
|
// The native speed damper only throttles backed-up output, so full load keeps its unobstructed value of 1.
|
|
var perMinute = ProductionUnits.TicksPerMinute * ProductionUnits.FixedPointScale /
|
|
building.MiningPeriodTicks * miningSpeed * machineSpeed * resourceFactor;
|
|
var powerRatio = machineSpeed * machineSpeed;
|
|
var workingWatts = building.WorkingPowerWatts * powerRatio +
|
|
building.IdlePowerWatts * (1 - powerRatio);
|
|
if (!FinitePositive(perMinute) || workingWatts < 0 ||
|
|
double.IsNaN(workingWatts) || double.IsInfinity(workingWatts))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
|
"The mineral output rate or power demand is outside the supported range.",
|
|
buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
process = new ProductionProcess(0, building.ItemId, ProliferationMode.None, 0,
|
|
Array.Empty<KeyValuePair<int, double>>(),
|
|
new[] { new KeyValuePair<int, double>((int)outputId, 1) },
|
|
perMinute, workingWatts, true);
|
|
return true;
|
|
}
|
|
|
|
private static bool ValidItemId(double value)
|
|
{
|
|
return value > 0 && value <= int.MaxValue && value == Math.Truncate(value);
|
|
}
|
|
|
|
private static bool FinitePositive(double value)
|
|
{
|
|
return value > 0 && !double.IsNaN(value) && !double.IsInfinity(value);
|
|
}
|
|
}
|