Files
DSP_Mods/UXAssist/Production/AccumulatorExchangeAdapter.cs
T
soarqin 97f032a5af feat(production): add shared planner and factory analysis
Add Proto-backed planning, fixed-building analysis, blueprint capture, and facility-specific material and power calculations.

Migrate belt-signal upstream statistics, include review fixes, and document the architecture and manual validation workflow.
2026-10-25 22:01:05 +08:00

135 lines
6.4 KiB
C#

using System;
using System.Collections.Generic;
using System.Linq;
namespace UXAssist.Production;
public sealed class AccumulatorExchangeAdapter : IProductionProcessAdapter
{
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
{
return recipe?.Category == ProductionRecipeCategory.Exchange ||
recipe == null && building?.Kind == ProductionBuildingKind.Exchanger;
}
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
out ProductionProcess process, out ProductionDiagnostic diagnostic)
{
process = null;
diagnostic = null;
if (building != null && building.Kind != ProductionBuildingKind.Exchanger)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
"This building cannot charge or discharge accumulators.", recipeId: recipe?.Id ?? 0,
buildingItemId: building.ItemId);
return false;
}
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"Accumulator exchange supports native speedup only.", recipeId: recipe?.Id ?? 0);
return false;
}
var speedBonus = 0.0;
if (mode != ProliferationMode.None &&
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out _, out _)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"The accumulator proliferation level is unavailable.", recipeId: recipe?.Id ?? 0);
return false;
}
var state = 0;
if (recipe != null)
{
if (recipe.Inputs.Count != 1 || recipe.Outputs.Count != 1 ||
recipe.Inputs.Single().Value != 1 || recipe.Outputs.Single().Value != 1)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
"Accumulator exchange requires one empty/full item conversion.", recipeId: recipe.Id);
return false;
}
var inputId = recipe.Inputs.Single().Key;
var outputId = recipe.Outputs.Single().Key;
state = building == null || inputId == building.EmptyAccumulatorItemId &&
outputId == building.FullAccumulatorItemId ? 1 :
inputId == building.FullAccumulatorItemId &&
outputId == building.EmptyAccumulatorItemId ? -1 : 0;
if (state == 0)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The exchanger's accumulator items do not match the recipe.", recipeId: recipe.Id);
return false;
}
}
else if (operatingParameters == null ||
!operatingParameters.TryGetValue("Mode0", out var selectedMode) ||
double.IsNaN(selectedMode) || double.IsInfinity(selectedMode) ||
selectedMode != Math.Truncate(selectedMode) ||
selectedMode < -1 || selectedMode > 1)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Provide the exchanger's native charging, discharging, or idle mode.",
buildingItemId: building?.ItemId ?? 0);
return false;
}
else
{
state = (int)selectedMode;
}
if (recipe != null && operatingParameters != null &&
operatingParameters.TryGetValue("Mode0", out var requestedMode) && requestedMode != state)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The exchanger's operating mode conflicts with the selected recipe.", recipeId: recipe.Id);
return false;
}
var inputItem = recipe?.Inputs.Single().Key ??
(state == 1 ? building.EmptyAccumulatorItemId : building.FullAccumulatorItemId);
var outputItem = recipe?.Outputs.Single().Key ??
(state == 1 ? building.FullAccumulatorItemId : building.EmptyAccumulatorItemId);
if (state != 0 && (inputItem <= 0 || outputItem <= 0))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"The exchanger's accumulator items are unavailable.", buildingItemId: building?.ItemId ?? 0);
return false;
}
if (building != null && state != 0 &&
(!FinitePositive(building.ExchangeRateWatts) || !FinitePositive(building.AccumulatorEnergyJoules)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"The exchanger's energy capacity is unavailable.", buildingItemId: building.ItemId);
return false;
}
var effectiveWatts = building == null || state == 0 ? 0 : building.ExchangeRateWatts * (1 + speedBonus);
var cycles = building == null ? 0 : state == 0 ? 1 :
effectiveWatts * 60 / building.AccumulatorEnergyJoules;
var inputs = state == 0 ? Array.Empty<KeyValuePair<int, double>>() :
new[] { new KeyValuePair<int, double>(inputItem, 1) };
var outputs = state == 0 ? Array.Empty<KeyValuePair<int, double>>() :
new[] { new KeyValuePair<int, double>(outputItem, 1) };
process = new ProductionProcess(recipe?.Id ?? 0, building?.ItemId ?? 0,
state == 0 ? ProliferationMode.None : mode, state == 0 ? 0 : level,
inputs, outputs, cycles, state == 1 ? effectiveWatts : building?.IdlePowerWatts ?? 0,
building != null, accumulatorChargingWatts: state == 1 ? effectiveWatts : 0,
accumulatorDischargingWatts: state == -1 ? effectiveWatts : 0,
sprayedInputsPerCycle: state == 0 ? 0 : 1,
preservedSpraysPerCycle: mode == ProliferationMode.None
? Array.Empty<KeyValuePair<int, double>>() : outputs);
return true;
}
private static bool FinitePositive(double value)
{
return value > 0 && !double.IsNaN(value) && !double.IsInfinity(value);
}
}