mirror of
https://github.com/soarqin/DSP_Mods.git
synced 2026-11-19 17:05:20 +08:00
Add Proto-backed planning, fixed-building analysis, blueprint capture, and facility-specific material and power calculations. Migrate belt-signal upstream statistics, include review fixes, and document the architecture and manual validation workflow.
96 lines
4.5 KiB
C#
96 lines
4.5 KiB
C#
using System;
|
|
using System.Collections.Generic;
|
|
|
|
namespace UXAssist.Production;
|
|
|
|
public sealed class FuelGenerationAdapter : IProductionProcessAdapter
|
|
{
|
|
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
|
|
{
|
|
return recipe == null && building?.Kind == ProductionBuildingKind.FuelGenerator;
|
|
}
|
|
|
|
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
|
|
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
|
|
out ProductionProcess process, out ProductionDiagnostic diagnostic)
|
|
{
|
|
process = null;
|
|
diagnostic = null;
|
|
if (operatingParameters == null ||
|
|
!operatingParameters.TryGetValue("FuelItemId", out var fuelId) ||
|
|
fuelId <= 0 || fuelId > int.MaxValue || fuelId != Math.Truncate(fuelId) ||
|
|
!catalog.Items.TryGetValue((int)fuelId, out var fuel) ||
|
|
fuel.HeatValueJoules <= 0 || (fuel.FuelTypeMask & building.FuelMask) == 0)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"Select a fuel item compatible with the generator's native fuel mask.",
|
|
buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup &&
|
|
mode != ProliferationMode.ExtraProducts ||
|
|
mode == ProliferationMode.ExtraProducts && !fuel.ProductiveFuel)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
|
"The fuel cannot use the requested proliferation mode.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
if (building.FuelUseWatts <= 0 || building.RatedGenerationWatts <= 0 ||
|
|
double.IsNaN(building.FuelUseWatts) || double.IsNaN(building.RatedGenerationWatts))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
|
|
"The generator's fuel consumption or power rating is unavailable.",
|
|
buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
var speedBonus = 0.0;
|
|
var extraBonus = 0.0;
|
|
if (mode != ProliferationMode.None &&
|
|
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out extraBonus, out _)))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
|
"The fuel's proliferation level is unavailable.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
var boostFactor = 1.0;
|
|
if (building.FuelMask == 4)
|
|
{
|
|
if (!operatingParameters.TryGetValue("Mode0", out var boostMode) ||
|
|
(boostMode != 0 && boostMode != 1))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"Select the artificial star's native boost setting.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
boostFactor = (boostMode == 1 ? 100 : 1) * fuel.StarOutputMultiplier;
|
|
}
|
|
|
|
var proliferationFactor = mode == ProliferationMode.None ? 1 :
|
|
fuel.ProductiveFuel ? 1 + extraBonus : 1 + speedBonus;
|
|
var generation = building.RatedGenerationWatts * proliferationFactor * boostFactor;
|
|
var burnedFuel = building.FuelUseWatts * (fuel.ProductiveFuel ? 1 : proliferationFactor) *
|
|
boostFactor * 60 / fuel.HeatValueJoules;
|
|
if (double.IsInfinity(generation) || double.IsInfinity(burnedFuel) || burnedFuel <= 0 ||
|
|
double.IsNaN(generation) || double.IsNaN(burnedFuel))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
|
"The selected fuel produces an invalid generation rate.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
process = new ProductionProcess(0, building.ItemId,
|
|
mode == ProliferationMode.None ? mode : fuel.ProductiveFuel
|
|
? ProliferationMode.ExtraProducts : ProliferationMode.Speedup,
|
|
mode == ProliferationMode.None ? 0 : level,
|
|
new[] { new KeyValuePair<int, double>(fuel.Id, 1) },
|
|
Array.Empty<KeyValuePair<int, double>>(), burnedFuel,
|
|
building.WorkingPowerWatts, true, generationWatts: generation);
|
|
return true;
|
|
}
|
|
}
|