Files
soarqin f0773ffb9b fix(production): correct blueprint power and planner edge cases
Read the Advanced Mining Machine speed stored with station settings in prebuild
and blueprint captures, and count charging power nodes such as Satellite
Substations at their idle draw. Skip recipes that consume their own product when
choosing an item's default recipe, so Refined Oil uses Plasma Refining instead
of Reforming Refine.

Run each planner recipe in one proliferation mode and report conflicting
explicit modes, keep material flows for recipe types the catalog does not know,
and attribute receiver warnings to their recipe. Compare simplex ratio ties
relatively and drive out near-zero artificials without amplifying residuals.
Bound the steady-state reduction so lossless cycles cannot stall blueprint
descriptions, and choose power units after rounding.

Remove redundant code: share the numeric and flow helpers, and drop the unused
IsExcessIntermediate threshold, legacy constructor and Capture overloads, the
multi-field updater, and the unused proliferator source table.
2026-10-25 22:01:05 +08:00

176 lines
8.5 KiB
C#

using System;
using System.Collections.Generic;
using static UXAssist.Production.ProductionMath;
namespace UXAssist.Production;
public sealed class RayReceiverAdapter : IProductionProcessAdapter
{
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
{
return building?.Kind == ProductionBuildingKind.RayReceiver ||
recipe?.Category == ProductionRecipeCategory.PhotonStore;
}
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
out ProductionProcess process, out ProductionDiagnostic diagnostic)
{
process = null;
diagnostic = null;
if (building == null)
return TryEvaluateWithoutReceiver(recipe, mode, operatingParameters, out process, out diagnostic);
if (building.Kind != ProductionBuildingKind.RayReceiver)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
"The selected building cannot receive Dyson-sphere rays.", recipeId: recipe?.Id ?? 0,
buildingItemId: building.ItemId);
return false;
}
if (!FinitePositive(building.RatedGenerationWatts) ||
(recipe != null && (recipe.Category != ProductionRecipeCategory.PhotonStore ||
recipe.Inputs.Count != 0 || recipe.Outputs.Count != 1 ||
!recipe.Outputs.ContainsKey(building.PowerProductItemId))))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
"The receiver's native photon product or power rating does not match the recipe.",
recipeId: recipe?.Id ?? 0, buildingItemId: building.ItemId);
return false;
}
var photonMode = recipe != null;
if (operatingParameters == null)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Provide the receiver's operating settings.", buildingItemId: building.ItemId);
return false;
}
var hasMode = operatingParameters.TryGetValue("Mode0", out var selectedMode);
if (!hasMode && !photonMode ||
hasMode && (selectedMode != 0 && selectedMode != building.PowerProductItemId ||
photonMode && selectedMode != building.PowerProductItemId))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Select the receiver's grid or native photon operating mode.",
recipeId: recipe?.Id ?? 0, buildingItemId: building.ItemId);
return false;
}
if (recipe == null && selectedMode > 0) photonMode = true;
if (photonMode && (building.PowerProductItemId <= 0 ||
!FinitePositive(building.PowerProductEnergyJoules) ||
!catalog.Items.ContainsKey(building.PowerProductItemId)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"The ray receiver has no valid native photon product or required photon energy.",
buildingItemId: building.ItemId);
return false;
}
if (!operatingParameters.TryGetValue("LensItemId", out var lensId) ||
lensId != 0 && !PositiveId(lensId))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"Provide the receiver's lens item ID, or zero for no lens.", buildingItemId: building.ItemId);
return false;
}
ProductionItem lens = null;
if (lensId > 0 && (!catalog.Items.TryGetValue((int)lensId, out lens) ||
(lens.CatalystTypeMask & building.CatalystMask) == 0 ||
!FinitePositive(lens.CatalystAbilityMultiplier)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The selected item is not a compatible ray-receiver lens.",
itemId: (int)lensId, buildingItemId: building.ItemId);
return false;
}
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup ||
mode == ProliferationMode.Speedup && lens == null)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"Only an installed lens can receive native ray-receiver speedup.", buildingItemId: building.ItemId);
return false;
}
var speedBonus = 0.0;
if (mode != ProliferationMode.None &&
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out _, out _)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
"The lens's proliferation level is unavailable.", buildingItemId: building.ItemId);
return false;
}
var energyWatts = building.RatedGenerationWatts * 2.5 *
(lens?.CatalystAbilityMultiplier ?? 1) *
(1 + speedBonus) * (photonMode ? 8 : 1);
var cyclesPerMinute = photonMode
? energyWatts * 60 / building.PowerProductEnergyJoules : 1;
if (!FinitePositive(cyclesPerMinute) || !Finite(energyWatts))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"The receiver's native output is outside the supported range.", buildingItemId: building.ItemId);
return false;
}
var lossKnown = operatingParameters.TryGetValue("SolarEnergyLossRate", out var solarLoss);
if (lossKnown && (solarLoss < 0 || solarLoss >= 1 || !Finite(solarLoss)))
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
"Solar energy loss must be a finite fraction below one.", buildingItemId: building.ItemId);
return false;
}
if (!lossKnown)
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
"The Dyson-sphere power requirement needs the current solar energy loss technology setting.",
recipeId: recipe?.Id ?? 0, buildingItemId: building.ItemId);
var lensFlow = lens == null ? Array.Empty<KeyValuePair<int, double>>() :
new[] { new KeyValuePair<int, double>(lens.Id, 0.1 / cyclesPerMinute) };
var productFlow = photonMode
? new[] { new KeyValuePair<int, double>(building.PowerProductItemId, 1) }
: Array.Empty<KeyValuePair<int, double>>();
process = new ProductionProcess(recipe?.Id ?? 0, building.ItemId, mode,
mode == ProliferationMode.None ? 0 : level, lensFlow, productFlow,
cyclesPerMinute, building.WorkingPowerWatts, true,
generationWatts: photonMode ? 0 : energyWatts,
dysonSphereRequirementWatts: lossKnown ? energyWatts / (1 - solarLoss * 0.6) : (double?)null,
powerKnown: lossKnown);
return true;
}
// Photon output per cycle does not depend on the receiver, but lens wear, speedup, and power do.
private static bool TryEvaluateWithoutReceiver(ProductionRecipe recipe, ProliferationMode mode,
IReadOnlyDictionary<string, double> operatingParameters, out ProductionProcess process,
out ProductionDiagnostic diagnostic)
{
process = null;
diagnostic = null;
if (recipe.Inputs.Count != 0 || recipe.Outputs.Count != 1)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
"A photon recipe must have one output and no inputs.", recipeId: recipe.Id);
return false;
}
if (mode != ProliferationMode.None ||
operatingParameters != null && operatingParameters.TryGetValue("LensItemId", out var lensId) &&
lensId != 0)
{
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingBuilding,
"Select a ray receiver to evaluate lens consumption and speedup.", recipeId: recipe.Id);
return false;
}
process = new ProductionProcess(recipe.Id, 0, ProliferationMode.None, 0,
Array.Empty<KeyValuePair<int, double>>(), recipe.Outputs, 0, 0, false);
return true;
}
}