Read the Advanced Mining Machine speed stored with station settings in prebuild and blueprint captures, and count charging power nodes such as Satellite Substations at their idle draw. Skip recipes that consume their own product when choosing an item's default recipe, so Refined Oil uses Plasma Refining instead of Reforming Refine. Run each planner recipe in one proliferation mode and report conflicting explicit modes, keep material flows for recipe types the catalog does not know, and attribute receiver warnings to their recipe. Compare simplex ratio ties relatively and drive out near-zero artificials without amplifying residuals. Bound the steady-state reduction so lossless cycles cannot stall blueprint descriptions, and choose power units after rounding. Remove redundant code: share the numeric and flow helpers, and drop the unused IsExcessIntermediate threshold, legacy constructor and Capture overloads, the multi-field updater, and the unused proliferator source table.
130 lines
6.2 KiB
C#
130 lines
6.2 KiB
C#
using System;
|
|
using System.Collections.Generic;
|
|
using System.Linq;
|
|
using static UXAssist.Production.ProductionMath;
|
|
|
|
namespace UXAssist.Production;
|
|
|
|
public sealed class AccumulatorExchangeAdapter : IProductionProcessAdapter
|
|
{
|
|
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
|
|
{
|
|
return recipe?.Category == ProductionRecipeCategory.Exchange ||
|
|
recipe == null && building?.Kind == ProductionBuildingKind.Exchanger;
|
|
}
|
|
|
|
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
|
|
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
|
|
out ProductionProcess process, out ProductionDiagnostic diagnostic)
|
|
{
|
|
process = null;
|
|
diagnostic = null;
|
|
if (building != null && building.Kind != ProductionBuildingKind.Exchanger)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.IncompatibleBuilding,
|
|
"This building cannot charge or discharge accumulators.", recipeId: recipe?.Id ?? 0,
|
|
buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
|
"Accumulator exchange supports native speedup only.", recipeId: recipe?.Id ?? 0);
|
|
return false;
|
|
}
|
|
|
|
var speedBonus = 0.0;
|
|
if (mode != ProliferationMode.None &&
|
|
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out _, out _)))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
|
"The accumulator proliferation level is unavailable.", recipeId: recipe?.Id ?? 0);
|
|
return false;
|
|
}
|
|
|
|
var state = 0;
|
|
if (recipe != null)
|
|
{
|
|
if (recipe.Inputs.Count != 1 || recipe.Outputs.Count != 1 ||
|
|
recipe.Inputs.Single().Value != 1 || recipe.Outputs.Single().Value != 1)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
|
|
"Accumulator exchange requires one empty/full item conversion.", recipeId: recipe.Id);
|
|
return false;
|
|
}
|
|
|
|
var inputId = recipe.Inputs.Single().Key;
|
|
var outputId = recipe.Outputs.Single().Key;
|
|
state = building == null || inputId == building.EmptyAccumulatorItemId &&
|
|
outputId == building.FullAccumulatorItemId ? 1 :
|
|
inputId == building.FullAccumulatorItemId &&
|
|
outputId == building.EmptyAccumulatorItemId ? -1 : 0;
|
|
if (state == 0)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
|
"The exchanger's accumulator items do not match the recipe.", recipeId: recipe.Id);
|
|
return false;
|
|
}
|
|
}
|
|
else if (operatingParameters == null ||
|
|
!operatingParameters.TryGetValue("Mode0", out var selectedMode) ||
|
|
!Finite(selectedMode) || selectedMode != Math.Truncate(selectedMode) ||
|
|
selectedMode < -1 || selectedMode > 1)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"Provide the exchanger's native charging, discharging, or idle mode.",
|
|
buildingItemId: building?.ItemId ?? 0);
|
|
return false;
|
|
}
|
|
else
|
|
{
|
|
state = (int)selectedMode;
|
|
}
|
|
|
|
if (recipe != null && operatingParameters != null &&
|
|
operatingParameters.TryGetValue("Mode0", out var requestedMode) && requestedMode != state)
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
|
"The exchanger's operating mode conflicts with the selected recipe.", recipeId: recipe.Id);
|
|
return false;
|
|
}
|
|
|
|
var inputItem = recipe?.Inputs.Single().Key ??
|
|
(state == 1 ? building.EmptyAccumulatorItemId : building.FullAccumulatorItemId);
|
|
var outputItem = recipe?.Outputs.Single().Key ??
|
|
(state == 1 ? building.FullAccumulatorItemId : building.EmptyAccumulatorItemId);
|
|
if (state != 0 && (inputItem <= 0 || outputItem <= 0))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"The exchanger's accumulator items are unavailable.", buildingItemId: building?.ItemId ?? 0);
|
|
return false;
|
|
}
|
|
|
|
if (building != null && state != 0 &&
|
|
(!FinitePositive(building.ExchangeRateWatts) || !FinitePositive(building.AccumulatorEnergyJoules)))
|
|
{
|
|
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
|
"The exchanger's energy capacity is unavailable.", buildingItemId: building.ItemId);
|
|
return false;
|
|
}
|
|
|
|
var effectiveWatts = building == null || state == 0 ? 0 : building.ExchangeRateWatts * (1 + speedBonus);
|
|
var cycles = building == null ? 0 : state == 0 ? 1 :
|
|
effectiveWatts * 60 / building.AccumulatorEnergyJoules;
|
|
var inputs = state == 0 ? Array.Empty<KeyValuePair<int, double>>() :
|
|
new[] { new KeyValuePair<int, double>(inputItem, 1) };
|
|
var outputs = state == 0 ? Array.Empty<KeyValuePair<int, double>>() :
|
|
new[] { new KeyValuePair<int, double>(outputItem, 1) };
|
|
process = new ProductionProcess(recipe?.Id ?? 0, building?.ItemId ?? 0,
|
|
state == 0 ? ProliferationMode.None : mode, state == 0 ? 0 : level,
|
|
inputs, outputs, cycles, state == 1 ? effectiveWatts : building?.IdlePowerWatts ?? 0,
|
|
building != null, accumulatorChargingWatts: state == 1 ? effectiveWatts : 0,
|
|
accumulatorDischargingWatts: state == -1 ? effectiveWatts : 0,
|
|
sprayedInputsPerCycle: state == 0 ? 0 : 1,
|
|
preservedSpraysPerCycle: mode == ProliferationMode.None
|
|
? Array.Empty<KeyValuePair<int, double>>() : outputs);
|
|
return true;
|
|
}
|
|
}
|