feat(production): add shared planner and factory analysis
Add Proto-backed planning, fixed-building analysis, blueprint capture, and facility-specific material and power calculations. Migrate belt-signal upstream statistics, include review fixes, and document the architecture and manual validation workflow.
This commit is contained in:
1 parent
d52bf1034a
commit
bcc82e1056
30 files changed
+5041
-250
No files matched your search
@@ -0,0 +1,95 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
|
||||
namespace UXAssist.Production;
|
||||
|
||||
public sealed class FuelGenerationAdapter : IProductionProcessAdapter
|
||||
{
|
||||
public bool CanEvaluate(ProductionRecipe recipe, ProductionBuilding building)
|
||||
{
|
||||
return recipe == null && building?.Kind == ProductionBuildingKind.FuelGenerator;
|
||||
}
|
||||
|
||||
public bool TryEvaluate(ProductionCatalog catalog, ProductionRecipe recipe, ProductionBuilding building,
|
||||
ProliferationMode mode, int level, IReadOnlyDictionary<string, double> operatingParameters,
|
||||
out ProductionProcess process, out ProductionDiagnostic diagnostic)
|
||||
{
|
||||
process = null;
|
||||
diagnostic = null;
|
||||
if (operatingParameters == null ||
|
||||
!operatingParameters.TryGetValue("FuelItemId", out var fuelId) ||
|
||||
fuelId <= 0 || fuelId > int.MaxValue || fuelId != Math.Truncate(fuelId) ||
|
||||
!catalog.Items.TryGetValue((int)fuelId, out var fuel) ||
|
||||
fuel.HeatValueJoules <= 0 || (fuel.FuelTypeMask & building.FuelMask) == 0)
|
||||
{
|
||||
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
||||
"Select a fuel item compatible with the generator's native fuel mask.",
|
||||
buildingItemId: building.ItemId);
|
||||
return false;
|
||||
}
|
||||
|
||||
if (mode != ProliferationMode.None && mode != ProliferationMode.Speedup &&
|
||||
mode != ProliferationMode.ExtraProducts ||
|
||||
mode == ProliferationMode.ExtraProducts && !fuel.ProductiveFuel)
|
||||
{
|
||||
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
||||
"The fuel cannot use the requested proliferation mode.", buildingItemId: building.ItemId);
|
||||
return false;
|
||||
}
|
||||
|
||||
if (building.FuelUseWatts <= 0 || building.RatedGenerationWatts <= 0 ||
|
||||
double.IsNaN(building.FuelUseWatts) || double.IsNaN(building.RatedGenerationWatts))
|
||||
{
|
||||
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProcess,
|
||||
"The generator's fuel consumption or power rating is unavailable.",
|
||||
buildingItemId: building.ItemId);
|
||||
return false;
|
||||
}
|
||||
|
||||
var speedBonus = 0.0;
|
||||
var extraBonus = 0.0;
|
||||
if (mode != ProliferationMode.None &&
|
||||
(level <= 0 || !catalog.TryGetProliferation(level, out speedBonus, out extraBonus, out _)))
|
||||
{
|
||||
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.UnsupportedProliferation,
|
||||
"The fuel's proliferation level is unavailable.", buildingItemId: building.ItemId);
|
||||
return false;
|
||||
}
|
||||
|
||||
var boostFactor = 1.0;
|
||||
if (building.FuelMask == 4)
|
||||
{
|
||||
if (!operatingParameters.TryGetValue("Mode0", out var boostMode) ||
|
||||
(boostMode != 0 && boostMode != 1))
|
||||
{
|
||||
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.MissingOperatingParameter,
|
||||
"Select the artificial star's native boost setting.", buildingItemId: building.ItemId);
|
||||
return false;
|
||||
}
|
||||
|
||||
boostFactor = (boostMode == 1 ? 100 : 1) * fuel.StarOutputMultiplier;
|
||||
}
|
||||
|
||||
var proliferationFactor = mode == ProliferationMode.None ? 1 :
|
||||
fuel.ProductiveFuel ? 1 + extraBonus : 1 + speedBonus;
|
||||
var generation = building.RatedGenerationWatts * proliferationFactor * boostFactor;
|
||||
var burnedFuel = building.FuelUseWatts * (fuel.ProductiveFuel ? 1 : proliferationFactor) *
|
||||
boostFactor * 60 / fuel.HeatValueJoules;
|
||||
if (double.IsInfinity(generation) || double.IsInfinity(burnedFuel) || burnedFuel <= 0 ||
|
||||
double.IsNaN(generation) || double.IsNaN(burnedFuel))
|
||||
{
|
||||
diagnostic = new ProductionDiagnostic(ProductionDiagnosticCode.InvalidRequest,
|
||||
"The selected fuel produces an invalid generation rate.", buildingItemId: building.ItemId);
|
||||
return false;
|
||||
}
|
||||
|
||||
process = new ProductionProcess(0, building.ItemId,
|
||||
mode == ProliferationMode.None ? mode : fuel.ProductiveFuel
|
||||
? ProliferationMode.ExtraProducts : ProliferationMode.Speedup,
|
||||
mode == ProliferationMode.None ? 0 : level,
|
||||
new[] { new KeyValuePair<int, double>(fuel.Id, 1) },
|
||||
Array.Empty<KeyValuePair<int, double>>(), burnedFuel,
|
||||
building.WorkingPowerWatts, true, generationWatts: generation);
|
||||
return true;
|
||||
}
|
||||
}
|
||||
Reference in new issue