fix(production): correct full-load capture and solver scaling

Stop capturing the transient miner output damper, apply the sandbox boost state to artificial stars as for launchers, and keep lens-free photon flows when no ray receiver is selected.

Scale the planner conservation check by each ledger row and normalize the simplex right-hand side so large rates no longer fail. Skip non-production objects before copying native settings, decode blueprints through the native paste path, and simplify analyzer mode resolution.

Update stale ProductionCheck expectations, add regression checks, and document the rules.
This commit is contained in:
soarqin committed 2026-10-25 22:01:05 +08:00
1 parent 97f032a5af
commit 51e90a8e1d
13 files changed
+418 -254

No files matched your search

+28 -29
View File
@@ -145,36 +145,9 @@ public sealed class FactoryBlackBoxAnalyzer
continue;
}
if (snapshot.SpeedFactor.HasValue)
building = new ProductionBuilding(building.ItemId, building.Category, snapshot.SpeedFactor.Value,
building.WorkingPowerWatts, building.IdlePowerWatts, building.Kind,
building.RatedGenerationWatts, building.ExchangeRateWatts,
building.AccumulatorEnergyJoules, building.EmptyAccumulatorItemId,
building.FullAccumulatorItemId, building.RenewableSource,
building.MinerKind, building.MiningPeriodTicks,
building.FuelMask, building.FuelUseWatts,
building.PowerProductItemId, building.PowerProductEnergyJoules,
building.CatalystMask, building.LaunchChargeTicks,
building.LaunchCooldownTicks, building.AmmunitionItemId,
building.CollectorSpeedMultiplier);
if (snapshot.SpeedFactor.HasValue) building = building.WithSpeedFactor(snapshot.SpeedFactor.Value);
var mode = request.ProliferationEnabled
? building.Kind == ProductionBuildingKind.Fractionator
? ProliferationMode.Speedup : building.Kind == ProductionBuildingKind.Exchanger &&
snapshot.OperatingParameters.TryGetValue("Mode0", out var exchangerMode) && exchangerMode != 0
? ProliferationMode.Speedup : building.Kind == ProductionBuildingKind.FuelGenerator
? ProliferationMode.Speedup : building.Kind == ProductionBuildingKind.RayReceiver
? snapshot.OperatingParameters.TryGetValue("LensItemId", out var lensId) && lensId > 0
? ProliferationMode.Speedup : ProliferationMode.None
: building.Kind == ProductionBuildingKind.Collector
? ProliferationMode.None
: building.Category == ProductionRecipeCategory.Research && snapshot.RecipeId == 0 &&
snapshot.OperatingParameters.TryGetValue("ResearchMode", out var researchModeSetting) &&
researchModeSetting > 0 ? ProliferationMode.ExtraProducts
: building.Kind == ProductionBuildingKind.Ejector ||
building.Kind == ProductionBuildingKind.Silo
? ProliferationMode.Speedup
: snapshot.ProliferationMode
: ProliferationMode.None;
? FullProliferationMode(building, snapshot) : ProliferationMode.None;
if (!_evaluator.TryEvaluate(_catalog, recipe, building, mode,
mode == ProliferationMode.None ? 0 : _catalog.MaximumProliferationLevel,
snapshot.OperatingParameters, out var process, out var diagnostic))
@@ -250,6 +223,32 @@ public sealed class FactoryBlackBoxAnalyzer
return new ProductionReport(status, materialComplete, powerComplete, flows, groups, diagnostics, power);
}
private static ProliferationMode FullProliferationMode(ProductionBuilding building,
ProductionBuildingSnapshot snapshot)
{
var parameters = snapshot.OperatingParameters;
switch (building.Kind)
{
case ProductionBuildingKind.Fractionator:
case ProductionBuildingKind.FuelGenerator:
case ProductionBuildingKind.Ejector:
case ProductionBuildingKind.Silo:
return ProliferationMode.Speedup;
case ProductionBuildingKind.Exchanger:
return parameters.TryGetValue("Mode0", out var exchangerMode) && exchangerMode != 0
? ProliferationMode.Speedup : snapshot.ProliferationMode;
case ProductionBuildingKind.RayReceiver:
return parameters.TryGetValue("LensItemId", out var lensId) && lensId > 0
? ProliferationMode.Speedup : ProliferationMode.None;
case ProductionBuildingKind.Collector:
return ProliferationMode.None;
default:
return building.Category == ProductionRecipeCategory.Research && snapshot.RecipeId == 0 &&
parameters.TryGetValue("ResearchMode", out var researchMode) && researchMode > 0
? ProliferationMode.ExtraProducts : snapshot.ProliferationMode;
}
}
private static Dictionary<int, double> Scale(IReadOnlyDictionary<int, double> flows, double factor)
{
return flows.ToDictionary(entry => entry.Key, entry => entry.Value * factor);